PN UPOL-OL300EP-CG01B
EAN6422956009489
Power
3000 VA / 2400 W
Type
On-line
Nominal Input Voltage
220-240 VAC
Nominal Output Voltage
208/220/230/240 VAC – user selectable
Frequency
50Hz / 60 Hz - user selectable
Outlets
4 x Schuko and Hard Wiring
Transfer Time to Battery / AC
Typical 0 ms
Eco mode 4 ms
Typical Backup Time
25% Load - 18 min
50% Load - 7 min
75% Load - 2 min
100% Load - 1 min
Communication Ports
HID USB, RS232, EPO, SNMP
Battery Type
Sealed and leak proof maintenance
Battery Specification
6 x GP07122L
Software
Monitor Control over USB, LAN and Internet (SNMP card optional)
Features
Online (double conversion)
Pure sine wave output
Selectable output voltage by user
Selectable output frequency by user
Wide Input Range (80V-300V)
Up to 96% Efficiency Rates
Software management
HID USB, RS2322. SNMP port communication
Generator Compatible
Auto-restart
Auto-charge
Low noise level
LCD Display
Load level, Battery level, AC mode, Battery mode, Bypass mode, Fault indicators
Environment
Humidity: 0-90 % (non-condensing)
Temperature: 0-40 grades Celsius
Noise level: less than 40 dB
Physical Dimensions
Dimensions: 416 x 196 x 342 mm
Weight: 25.1 kg
PN PWUP-OL300AP-AZ01B EAN6422956007737 Power 3000 Va / 2700 W Nominal Input Voltage 230Vac Nominal Output Voltage 200*/208*/220/230/240 VAC *Derate capacity to 80% when the output voltage is adjusted to 200VAC/208VAC Accepted Input Voltage Range 110-300 VAC ± 5% @ 50% load 160-300 VAC ± 5% @ 100% load Frequency 50 / 60 Hz Auto detection Outlets 4 x Schuko outlets with protection Transfer Time to Battery / AC AC-DC: Zero Inverter to Bypass: 4ms Com
Power 2000 VA / 1600 W Type On-line Nominal Input Voltage 220-240 VAC Nominal Output Voltage 208/220/230/240 VAC – user selectable Frequency 50Hz / 60 Hz - user selectable Outlets 4 x Schuko Battery Backup Surge Protection Transfer Time to Battery / AC Typical 0 ms Eco mode 4 ms Typical Backup Time 25% Load - 17 min 50% Load - 7 min 75% Load - 3 min 100% Load - 1 min Communication Ports HID USB, RS232, EPO, SNMP Battery Type Sealed and l
PN UPOL-OL100EP-CG01B EAN6422956009465 Power 1000 VA / 800 W Type On-line Nominal Input Voltage 220-240 VAC Nominal Output Voltage 208/220/230/240 VAC – user selectable Frequency 50Hz / 60 Hz - user selectable Outlets 3 x Schuko Battery Backup Surge Protection Transfer Time to Battery / AC Typical 0 ms Eco mode 4 ms Typical Backup Time 25% Load - 19 min 50% Load - 6 min 75% Load - 2 min 100% Load - 1 min Communication Ports HID USB, RS
NJOY Szünetmentes 600VA - Keen 600 (2 Schuko, line-interaktív, RJ11/45 vonalvédelem, fekete)
PN PWUP-OL100AP-AZ01B EAN6422956007713 Power 1000VA / 900W Type On-line Nominal Input Voltage 110-300 Vac Nominal Output Voltage 230 Vac Accepted Input Voltage Range ±1% (in Battery Mode) Frequency 40Hz ~ 70Hz Outlets 3 Outlets with Battery Backup Surge Protection Transfer time AC-DC: Zero Inverter to Bypass: 4ms LCD Display AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault and Low Battery
PN PWUP-OL200AP-AZ01B EAN6422956007720 Power 2000VA / 1800W Nominal Input Voltage 230Vac Accepted Input Voltage Range 110-300Vac Nominal Output Voltage 230Vac Frequency 40Hz ~ 70Hz Outlets 3 Outlets with Battery Backup Surge Protection Transfer time AC-DC: Zero Inverter to Bypass: 4ms LCD Display AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault and Low Battery Communication Port USB RS232
Power 600 VA / 360 W Type Line Interactive Nominal Input Voltage 230 Vac Nominal Output Voltage 230Vac Accepted Input Voltage Range 170-280 VAC Frequency 60/50 Hz (auto sensing) Outlets 4 x Schuko outlets with protection RJ45/RJ11 Protection 1 in / 1 out Transfer time 2-6 ms Typical Backup Time 25% Load - 10 min 50% Load - 4 min 75% Load -
PN UPLI-LI060KU-CG01B EAN6422956009540 Power 600 VA / 360 W Type Line Interactive Nominal Input Voltage 230 Vac Nominal Output Voltage 230 Vac Frequency 50Hz ~ 60Hz (Auto Sensing) Outlets 2 x Schuko Battery Backup Surge Protection Transfer Time to Battery / AC Typical 4 ms Typical Backup Time 25% Load - 19 min 50% Load - 5 min 75% Load - 1 min 100% Load -
PN UPLI-LI080KU-CG01B EAN6422956009557 Power 800 VA / 480 W Type Line Interactive Nominal Input Voltage 230 Vac Nominal Output Voltage 230 Vac Accepted Input Voltage Range 162 ~ 290 VAC Frequency 50Hz ~ 60Hz (Auto Sensing) Outlets 2 x Schuko Battery Backup Surge Protection Transfer Time to Battery / AC Typical 4 ms Typical Backup Time 25% Load - 18 min 50% Load - 3 min 75% Load - 1 min 100% Load -
PN UPCSTLP860TAICP01B EAN6422956011666 Power 600 VA / 500 W Accepted Input Voltage Range 145~275 VAC Nominal Input Voltage 230Vac Accepted Output Voltage Range 213~248VAC Nominal Output Voltage 230Vac Type Line Interactive Frequency 50Hz Outlets 2 x Schuko Battery Backup Surge Protection Transfer Time to Battery / AC
Power 3000 VA / 1800 W Type Line Interactive Nominal Input Voltage 230 Vac Accepted Input Voltage Range 165 - 290 VAC Nominal Output Voltage 230 Vac Frequency 50Hz ~ 60 Hz (Auto sensing) Transfer Time to Battery / AC < 4 ms LCD Display Load level, Battery level, AC mode, Battery mode and Fault indicators Outlets 8 x IEC C13 Battery Backup Surge Protection Battery Type Sealed and leak proof maintenance Battery Specification 12V 7.5Ah x 4 Battery Compatibility PW9123 Typical Backup Time 25% Loa
12+12 hó, 3000VA (2400W), On-line, Rack, RS232 / USB, LCD
12+12 hó, 3000VA (2700W), On-line, Torony, RS232 / USB, LCD
PN UPLI-LI150KU-CG01B EAN6422956009571 Power 1500 VA / 900 W Type Line Interactive Nominal Input Voltage 230 Vac Nominal Output Voltage 230 Vac Accepted Input Voltage Range 162 ~ 290 VAC Frequency 50Hz ~ 60Hz (Auto Sensing) Outlets 4 Outlets with Battery Backup Surge Protection Transfer Time to Battery / AC Typical 4 ms Typical Backup Time 25% Load - 22 min 50% Load - 8 min 75% Load - 2 min 100% Load -
PN UPCSBLS660TTOAZ01B EAN6422956011499 Power 600 VA / 360 W Type Line Interactive Nominal Input Voltage 230Vac Accepted Input Voltage Range 170 – 280 VAC Frequency 50Hz ~ 60Hz (Auto Sensing) Outlets 4x Schuko Battery Backup 4x Schuko Surge Protection Transfer Time to Battery / AC 6ms Typical Backup Time 25% Load - 15min 50% Load - 5min 30s 75% Load - 0min 40s Communication Port HID USB Software https://www.power-softwaredownload.